Oscilloscope Counter Preamp

Compartir:
The circuit will provide a 20 0.1 dB voltage gain from 500 kHz to 50 MHz. The low-frequency response of the amplifier can be extended by increasing the value of the 0.05-mF capacitor connected in series with the input terminal. This circuit will yield an input-noise level of approximately 10 V over a 15.7-Mhz bandwidth. The gain can be calibrated by adjusting the potentiometer connected between pins 4 and 11. The 1-KW potentiometer can be adjusted for an exact voltage gain of 10. This preserves the scale factor of the instrument.

Click para ampliar